Show simple item record

dc.contributor.authorSchanke, Charlotte Marie
dc.contributor.authorBrekka, Anne Kristine
dc.contributor.authorRimehaug, Stein Arne
dc.contributor.authorKlokkerud, Mari
dc.contributor.authorAndersen, Tiina Maarit
dc.date.accessioned2024-01-18T11:59:15Z
dc.date.available2024-01-18T11:59:15Z
dc.date.created2023-09-07T09:36:54Z
dc.date.issued2023
dc.identifier.citationJournal of Clinical Medicine. 2023, 12 (15), .en_US
dc.identifier.issn2077-0383
dc.identifier.urihttps://hdl.handle.net/11250/3112471
dc.description.abstractBackground: Assessment of physical and respiratory function in the intensive care unit (ICU) is useful for developing an individualized treatment plan and evaluating patient progress. There is a need for measurement tools that are culturally adapted, reliable and easy to use. The Chelsea Critical Care Physical Assessment Tool (CPAx) is a valid measurement tool with strong psychometric properties for the intensive care population. This study aims to translate, adapt and test face validity and inter-rater reliability of the Norwegian version of CPAx (CPAx-NOR) for use in critically ill adult patients receiving prolonged mechanical ventilation. Method: CPAx-NOR was forward backward translated, culturally adapted and tested by experts and patients for face validity. Thereafter tested by 10 physiotherapists in five hospitals for inter-rater reliability. Results: The experts and pilot testers reached consensus on the translation and face validity. Patients were tested at time point A (n = 57) and at time point B (n = 53). The reliability of CPAx-NOR at “A” was 0.990 (0.983–0.994) and at “B” 0.994 (0.990–0.997). Based on A+B combined and adjusted, the ICC was 0.990 (95% CI 0.996–0.998). Standard error of measurement (SEM) was 0.68 and the minimal detectable change (MDC) was 1.89. The Bland–Altman plot showed low bias and no sign of heteroscedasticity. CPAx-NOR changed with a mean score of 14.9, and showed a moderate floor effect at the start of physiotherapy and low ceiling effects at discharge. Conclusion: CPAx-NOR demonstrated good face validity and excellent inter-rater reliability. It can be used as an assessment tool for physical function in critically ill adults receiving prolonged mechanical ventilation in Norway. Keywords: physiotherapy; physical function; early rehabilitation; measurement tool; critical illness; CPAx; critical careen_US
dc.language.isoengen_US
dc.publisherMDPIen_US
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleNorwegian Version of the Chelsea Critical Care Physical Assessment Tool (CPAx-NOR): Translation, Face Validity, Cross-Cultural Adaptation and Inter-Rater Reliabilityen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.rights.holder© 2023 by the authorsen_US
dc.source.pagenumber0en_US
dc.source.volume12en_US
dc.source.journalJournal of Clinical Medicineen_US
dc.source.issue15en_US
dc.identifier.doi10.3390/jcm12155033
dc.identifier.cristin2173096
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Navngivelse 4.0 Internasjonal
Except where otherwise noted, this item's license is described as Navngivelse 4.0 Internasjonal