Vis enkel innførsel

dc.contributor.authorSetterdahl, Lena Marie
dc.contributor.authorLionheart, William R. B.
dc.contributor.authorHolman, Sean F.
dc.contributor.authorSkjerdal, Kyrre
dc.contributor.authorRatliff, Hunter Nathaniel
dc.contributor.authorYtre-Hauge, Kristian Smeland
dc.contributor.authorLathouwers, Danny
dc.contributor.authorMeric, Ilker
dc.date.accessioned2024-08-22T10:59:57Z
dc.date.available2024-08-22T10:59:57Z
dc.date.created2024-08-13T07:41:37Z
dc.date.issued2024
dc.identifier.issn0302-9743
dc.identifier.urihttps://hdl.handle.net/11250/3147557
dc.descriptionThis is an Accepted Manuscript of an article published by SpringerNature in Medical Image Understanding and Analysis 28th Annual Conference, MIUA 2024, Manchester, UK, July 24–26, 2024, Proceedings, Part I. The Version of Record is available from https://doi.org/10.1007/978-3-031-66955-2_16en_US
dc.description.abstractThis study aims to investigate the capability of U-Nets in improving image reconstruction accuracy for proton range verification within the framework of the NOVO (Next generation imaging for real-time dose verification enabling adaptive proton therapy) project. NOVO aims to enhance the accuracy of proton range verification by imaging the distribution of prompt gamma-rays (PGs) and fast neutrons (FNs) produced by nuclear interactions within tissue. In this work, focus lies on FNs, leaving PGs as future work. A dataset consisting of Monte Carlo-based simple back-projection and ground truth images of FN production distributions in a homogeneous water phantom was utilized. Various U-Net models were trained to predict FN distributions, and a set of range landmark (RL) metrics were computed for evaluation. Linear regression models were established to correlate shifts in mean RL with true range shift magnitudes. Our findings demonstrate a strong linear correlation between the shifts in mean RL in U-Net predictions and the true range shift magnitudes. Multiple RL metrics, including weighted average, inflection point, edge, and peak, were explored. This study highlights the potential utility of U-Nets in enhancing image reconstruction accuracy for proton range verification. The observed correlations between RL shifts and true range shifts provide evidence of the ability of U-Nets to accurately predict images containing range information. Future research will focus on generating more realistic training data incorporating more clinically relevant phantoms, including tissue heterogeneities.en_US
dc.language.isoengen_US
dc.publisherSpringerNatureen_US
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleImage Reconstruction for Proton Therapy Range Verification via U-NETsen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionacceptedVersionen_US
dc.source.pagenumber232-244en_US
dc.source.volume14859en_US
dc.source.journalLecture Notes in Computer Science (LNCS)en_US
dc.identifier.doi10.1007/978-3-031-66955-2_16
dc.identifier.cristin2285950
cristin.ispublishedtrue
cristin.fulltextpostprint
cristin.fulltextpostprint
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse 4.0 Internasjonal