Vis enkel innførsel

dc.contributor.authorAlme, Johan
dc.contributor.authorAlt, Torsten
dc.contributor.authorAndrei, C.
dc.contributor.authorAnguelov, V.
dc.contributor.authorAppelshäuser, H.
dc.contributor.authorArslandok, M.
dc.contributor.authorBarnaföldi, G.
dc.contributor.authorBartsch, E.
dc.contributor.authorBecht, P.
dc.contributor.authorBellwied, R.
dc.contributor.authorBerdnikova, A.
dc.contributor.authorBialas, N.
dc.contributor.authorBialas, P.
dc.contributor.authorBiswas, S.
dc.contributor.authorBlidaru, B.
dc.contributor.authorBoldizsár, L.
dc.contributor.authorBratrud, Lars Karlot Stubberud
dc.contributor.authorBraun-Munzinger, P.
dc.contributor.authorBregant, M.
dc.contributor.authorBritton, C.
dc.contributor.authorBrucker, S.
dc.contributor.authorBrücken, E.
dc.contributor.authorBüsching, H.
dc.contributor.authorSoto Camacho, Camacho
dc.contributor.authorCastro, A.
dc.contributor.authorChatzidaki, P.
dc.contributor.authorChristiansen, P.
dc.contributor.authorClonts, L.
dc.contributor.authorCormier, T.
dc.contributor.authorDhankher, P.
dc.contributor.authorDittrich, S.
dc.contributor.authorEhlers, R.
dc.contributor.authorEricson, M.
dc.contributor.authorEzell, N.
dc.contributor.authorFabbietti, L.
dc.contributor.authorFlor, F.
dc.contributor.authorGaardhøje, J.
dc.contributor.authorMunhoz, M.
dc.contributor.authorGarabatos, C.
dc.contributor.authorGasik, P.
dc.contributor.authorGeiger, T.
dc.contributor.authorGera, Á
dc.contributor.authorGlässel, P.
dc.contributor.authorGoh, D.
dc.contributor.authorGrein, A.
dc.contributor.authorGundem, T.
dc.contributor.authorGunji, T.
dc.contributor.authorHabib, M.
dc.contributor.authorHamagaki, H.
dc.contributor.authorHamar, G.
dc.contributor.authorHansen, J.
dc.contributor.authorHarris, J.
dc.contributor.authorHauer, P.
dc.contributor.authorHayashi, S.
dc.contributor.authorHehner, J.
dc.contributor.authorHeino, J.
dc.contributor.authorHellbär, E.
dc.contributor.authorHelstrup, Håvard
dc.contributor.authorHemmer, M.
dc.contributor.authorHerghelegiu, A.
dc.contributor.authorHernandez, R.
dc.contributor.authorHernandez Herrera, Herrera
dc.contributor.authorHilden, T.
dc.contributor.authorHughes, C.
dc.contributor.authorHummel, S.
dc.contributor.authorIvanov, M.
dc.contributor.authorJäger, J.
dc.contributor.authorJung, J.
dc.contributor.authorJung, M.
dc.contributor.authorKangasaho, E.
dc.contributor.authorKetzer, B.
dc.contributor.authorKirsch, S.
dc.contributor.authorKleiner, M.
dc.contributor.authorKlemenz, T.
dc.contributor.authorKnospe, A.
dc.contributor.authorKowalski, M.
dc.contributor.authorKreis, L.
dc.contributor.authorKrüger, M.
dc.contributor.authorKupfer, N.
dc.contributor.authorLang, R.
dc.contributor.authorLautner, L.
dc.contributor.authorLesch, M.
dc.contributor.authorLesenechal, Y.
dc.contributor.authorLiebske, F.
dc.contributor.authorLippmann, C.
dc.contributor.authorMajka, R.
dc.contributor.authorMarkert, C.
dc.contributor.authorMartins, T.
dc.contributor.authorMasciocchi, S.
dc.contributor.authorMatonoha, O.
dc.contributor.authorMatyja, A.
dc.contributor.authorMeres, M.
dc.contributor.authorMihaylov, D.
dc.contributor.authorMiśkowiec, D.
dc.contributor.authorMittelstaedt, T.
dc.contributor.authorMordasini, C.
dc.contributor.authorMorhardt, T.
dc.contributor.authorMuley, S.
dc.contributor.authorMulligan, J.
dc.contributor.authorMunzer, R.
dc.contributor.authorMurakami, H.
dc.contributor.authorMünning, K.
dc.contributor.authorNassirpour, A.
dc.contributor.authorNattrass, C.
dc.contributor.authorNielsen, B.
dc.contributor.authorNoije, W.
dc.contributor.authorOgino, M.
dc.contributor.authorOliveira Da Silva, Da
dc.contributor.authorOskarsson, A.
dc.contributor.authorOyama, K.
dc.contributor.authorÖnnerstad, A.
dc.contributor.authorÖsterman, L.
dc.contributor.authorPachmayer, Y.
dc.contributor.authorPaić, G.
dc.contributor.authorPatra, R.
dc.contributor.authorPeskov, V.
dc.contributor.authorPetris, M.
dc.contributor.authorPetrovici, M.
dc.contributor.authorPlaninic, M.
dc.contributor.authorProdan, L.
dc.contributor.authorRadu, A.
dc.contributor.authorRasson, J.
dc.contributor.authorRead, K.
dc.contributor.authorRehman, Attiq Ur
dc.contributor.authorRenfordt, R.
dc.contributor.authorRøed, Ketil
dc.contributor.authorRöhrich, Dieter Rudolf Christian
dc.contributor.authorRubio, E.
dc.contributor.authorRusu, A.
dc.contributor.authorSanches, B.
dc.contributor.authorSchambach, J.
dc.contributor.authorScheid, S.
dc.contributor.authorSchmidt, C.
dc.contributor.authorSchmier, A.
dc.contributor.authorSchweda, K.
dc.contributor.authorSekihata, D.
dc.contributor.authorSiebig, S.
dc.contributor.authorSilva, R.
dc.contributor.authorSilvermyr, D.
dc.contributor.authorSitar, B.
dc.contributor.authorSmirnov, N.
dc.contributor.authorSoltveit, H.
dc.contributor.authorSorensen, S.
dc.contributor.authorStachel, J.
dc.contributor.authorŠerkšnytė, L.
dc.contributor.authorTambave, Ganesh Jagannath
dc.contributor.authorUllaland, Kjetil
dc.contributor.authorUlukutlu, B.
dc.contributor.authorVarga, D.
dc.contributor.authorVazquez Rueda, Rueda
dc.contributor.authorVelure, Arild
dc.contributor.authorVergara Limón, Limon
dc.contributor.authorVorbach, O.
dc.contributor.authorVoss, B.
dc.contributor.authorWeidlich, C.
dc.contributor.authorWiechula, J.
dc.contributor.authorWindelband, B.
dc.contributor.authorWinkler, S.
dc.date.accessioned2024-01-26T07:10:13Z
dc.date.available2024-01-26T07:10:13Z
dc.date.created2024-01-05T08:38:03Z
dc.date.issued2023
dc.identifier.citationJournal of Instrumentation (JINST). 2023, 18 (11), .en_US
dc.identifier.issn1748-0221
dc.identifier.urihttps://hdl.handle.net/11250/3113981
dc.description.abstractTo operate the ALICE Time Projection Chamber in continuous mode during the Run 3 and Run 4 data-taking periods of the Large Hadron Collider, the multi-wire proportional chamber-based readout was replaced with gas-electron multipliers. As expected, the detector performance is affected by the so-called common-mode effect, which leads to significant baseline fluctuations. A detailed study of the pulse shape with the new readout has revealed that it is also affected by ion tails. Since reconstruction and data compression are performed fully online, these effects must be corrected at the hardware level in the FPGA-based common readout units. The characteristics of the common-mode effect and of the ion tail, as well as the algorithms developed for their online correction, are described in this paper. The common-mode dependencies are studied using machine-learning techniques. Toy Monte Carlo simulations are performed to illustrate the importance of online corrections and to investigate the performance of the developed algorithms.en_US
dc.language.isoengen_US
dc.publisherIOP Publishingen_US
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleCorrection of the baseline fluctuations in the GEM-based ALICE TPCen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.rights.holder© 2023 CERN for the benefit of the ALICE collaborationen_US
dc.source.pagenumber28en_US
dc.source.volume18en_US
dc.source.journalJournal of Instrumentation (JINST)en_US
dc.source.issue11en_US
dc.identifier.doi10.1088/1748-0221/18/11/P11021
dc.identifier.cristin2221021
dc.source.articlenumberP11021en_US
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse 4.0 Internasjonal