Vis enkel innførsel

dc.contributor.authorSteihaug, Ole Martin
dc.contributor.authorBogen, Bård Erik
dc.contributor.authorKristoffersen, Målfrid Holen
dc.contributor.authorRanhoff, Anette Hylen
dc.coverage.spatialBergen, Norwaynb_NO
dc.date.accessioned2019-03-28T10:03:55Z
dc.date.available2019-03-28T10:03:55Z
dc.date.created2017-08-28T11:18:40Z
dc.date.issued2017
dc.identifier.citationSteihaug, O. M., Bogen, B. E., Kristoffersen, M. H., & Ranhoff, A. H. (2017). Bones, blood and steel: How bioelectrical impedance analysis is affected by hip fracture and surgical implants. Journal of Electrical Bioimpedance, 8(1).nb_NO
dc.identifier.issn1891-5469
dc.identifier.urihttp://hdl.handle.net/11250/2592142
dc.description.abstractIntroduction: Bioelectrical impedance analysis (BIA) is in widespread use, but there is uncertainty about its validity in patients with metal implants or after acute hip fracture and surgery. We aimed to investigate the use of single frequency tetrapolar BIA in patients with hip fracture by answering the following questions: 1. Are BIA measurements affected by recent fracture and surgical repair? 2. Are BIA measurements affected by the presence of metal implants used in hip fracture surgery? Setting: Two hospitals in Bergen, Norway. Participants: A convenience sample of 203 acute hip fracture patients. Methods: Participants had their body composition measured by single frequency, tetrapolar BIA on the fractured and unfractured side of the body in the immediate postoperative period and at follow-up three months after hip fracture. Measurements from fractured and unfractured side and measurements in hospital and at follow-up were compared. BIA values for hips treated with cannulated screws, compression hip screw and hip arthroplasty were compared. Results: Resistance was lower on the side of the fractured hip compared to the unfractured side postoperatively, but not at follow-up. BIA values did not differ by type of surgical implant. Conclusion: Recent fracture and surgery influences single frequency tetrapolar BIA resistance. The presence of surgical implants in the hip do not affect BIA measurements. If BIA is used in acute hip fracture patients, the contralateral side to the fracture should be measured.nb_NO
dc.language.isoengnb_NO
dc.publisherJournal of Electrical Bioimpedancenb_NO
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.subjectbioelectrical impedance analysisnb_NO
dc.subjecthip fracturenb_NO
dc.subjectsurgical implantsnb_NO
dc.titleBones, blood and steel: How bioelectrical impedance analysis is affected by hip fracture and surgical implantsnb_NO
dc.typeJournal articlenb_NO
dc.typePeer reviewednb_NO
dc.description.versionpublishedVersionnb_NO
dc.rights.holder© 2017 by the authorsnb_NO
dc.subject.nsiVDP::Medisinske Fag: 700::Klinisk medisinske fag: 750::Ortopedisk kirurgi: 784nb_NO
dc.subject.nsiVDP::Medisinske Fag: 700::Klinisk medisinske fag: 750nb_NO
dc.source.pagenumber54-59nb_NO
dc.source.volume8nb_NO
dc.source.journalJournal of Electrical Bioimpedancenb_NO
dc.identifier.doi10.5617/jeb.4104
dc.identifier.cristin1489007
cristin.unitcode203,3,11,0
cristin.unitnameInstitutt for ergo/fysio/radio - Bergen
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse 4.0 Internasjonal