Vis enkel innførsel

dc.contributor.authorØynes, Mona
dc.contributor.authorStrøm, Bergliot
dc.contributor.authorTveito, Bente Gunn
dc.contributor.authorHafslund, Bjørg Norunn Rullestad
dc.date.accessioned2020-08-13T13:00:10Z
dc.date.available2020-08-13T13:00:10Z
dc.date.created2020-04-27T14:32:18Z
dc.date.issued2020
dc.identifier.citationØynes, M., Strøm, B., Tveito, B., & Hafslund, B. (2020). Digital zoom of the full-field digital mammogram versus magnification mammography: a systematic review. European Radiology, 30(8), 4223-4233.en_US
dc.identifier.issn0938-7994
dc.identifier.urihttps://hdl.handle.net/11250/2671918
dc.description.abstractObjectives To summarise and compare the performance of magnification mammography and digital zoom utilising a full-field digital mammography (FFDM) system in the detection and diagnosis of microcalcifications. Methods We ran an extended search in MEDLINE, EMBASE, CINAHL, Engineering Village and Web of Science. Diagnostic test studies, experimental breast phantom studies and a Monte Carlo phantom study were included. A narrative approach was selected to summarise and compare findings regarding the detection of microcalcifications, while a hierarchical model with bivariate analysis was used for the meta-analysis of sensitivity and specificity for diagnosing microcalcifications. Results Nine studies were included. Phantom studies suggested that the size of microcalcifications, magnification or zoom factor, exposure factors and detector technology determine whether digital zoom is equivalent to magnification mammography in the detection of microcalcifications. Pooled sensitivity for magnification and zoom calculated from the diagnostic test studies was 0.93 (95% CI 0.84–0.97) and 0.85 (95% CI 0.70–0.94), respectively. Pooled specificity was 0.55 (95% CI 0.51–0.58) and 0.56 (95% CI 0.50–0.62), respectively. The differences between the sensitivities and specificities were not statistically significant. Conclusions Digital zoom may be equivalent to magnification mammography. Diagnostic test studies and phantom studies using newer detector technology would contribute additional knowledge on this topic.en_US
dc.language.isoengen_US
dc.publisherSpringeren_US
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.subjectmammographyen_US
dc.subjectdiagnostic test, routineen_US
dc.subjectphantoms, imagingen_US
dc.subjectcalcinosisen_US
dc.titleDigital zoom of the full-field digital mammogram versus magnification mammography: a systematic reviewen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.rights.holder© The Author(s) 2020en_US
dc.subject.nsiVDP::Medisinske Fag: 700::Klinisk medisinske fag: 750::Radiologi og bildediagnostikk: 763en_US
dc.source.pagenumber4223-4233en_US
dc.source.volume3+en_US
dc.source.journalEuropean Radiologyen_US
dc.source.issue8en_US
dc.identifier.doi10.1007/s00330-020-06798-6
dc.identifier.cristin1808279
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode2


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse 4.0 Internasjonal