Show simple item record

dc.contributor.authorBrønd, Jan Christian
dc.contributor.authorAndersen, Lars Bo
dc.contributor.authorArvidsson, Daniel
dc.date.accessioned2019-04-11T08:22:32Z
dc.date.available2019-04-11T08:22:32Z
dc.date.created2017-11-24T13:02:18Z
dc.date.issued2017
dc.identifier.citationBrønd, J. C., Andersen, L. B., & Arvidsson, D. (2017). Generating actigraph counts from raw acceleration recorded by an alternative monitor. Medicine & Science in Sports & Exercise, 49(11), 2351-2360.nb_NO
dc.identifier.issn0195-9131
dc.identifier.urihttp://hdl.handle.net/11250/2594152
dc.descriptionAuthor's accepted manuscript (post-print).nb_NO
dc.description.abstractPurpose: This study aimed to implement an aggregation method in Matlab for generating ActiGraph counts from raw acceleration recorded with an alternative accelerometer device and to investigate the validity of the method. Methods: The aggregation method, including the frequency band-pass filter, was implemented and optimized based on standardized sinusoidal acceleration signals generated in Matlab and processed in the ActiLife software. Evaluating the validity of the aggregation method was approached using a mechanical setup and with a 24-h free-living recording using a convenient sample of nine subjects. Counts generated with the aggregation method applied to Axivity AX3 raw acceleration data were compared with counts generated with ActiLife from ActiGraph GT3X+ data. Results: An optimal band-pass filter was fitted resulting in a root-mean-square error of 25.7 counts per 10 s and mean absolute error of 15.0 counts per second across the full frequency range. The mechanical evaluation of the proposed aggregation method resulted in an absolute mean T SD difference of j0.11 T 0.97 counts per 10 s across all rotational frequencies compared with the original ActiGraph method. Applying the aggregation method to the 24-h free-living recordings resulted in an epoch level bias ranging from j16.2 to 0.9 counts per 10 s, a relative difference in the averaged physical activity (counts per minute) ranging from j0.5% to 4.7% with a group mean T SD of 2.2% T 1.7%, and a Cohen_s kappa of 0.945, indicating almost a perfect agreement in the intensity classification. Conclusion: The proposed band-pass filter and aggregation method is highly valid for generating ActiGraph counts from raw acceleration data recorded with alternative devices. It would facilitate comparability between studies using different devices collecting raw acceleration data.nb_NO
dc.language.isoengnb_NO
dc.publisherLippincott, Williams & Wilkinsnb_NO
dc.rightsNavngivelse-Ikkekommersiell 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/deed.no*
dc.subjectGT3X+nb_NO
dc.subjectphysical activitynb_NO
dc.subjectfilteringnb_NO
dc.subjectalgorithmsnb_NO
dc.subjectvalidationnb_NO
dc.titleGenerating actiGraph counts from raw acceleration recorded by an alternative monitornb_NO
dc.typeJournal articlenb_NO
dc.typePeer reviewednb_NO
dc.description.versionacceptedVersionnb_NO
dc.subject.nsiVDP::Medisinske Fag: 700::Idrettsmedisinske fag: 850nb_NO
dc.source.pagenumber2351-2360nb_NO
dc.source.volume49nb_NO
dc.source.journalMedicine & Science in Sports & Exercisenb_NO
dc.source.issue11nb_NO
dc.identifier.doi10.1249/MSS.0000000000001344
dc.identifier.cristin1518132
cristin.unitcode203,5,2,0
cristin.unitnameAvdeling for lærarutdanning og idrett - Sogn og Fjordane
cristin.ispublishedtrue
cristin.fulltextpostprint
cristin.qualitycode2


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Navngivelse-Ikkekommersiell 4.0 Internasjonal
Except where otherwise noted, this item's license is described as Navngivelse-Ikkekommersiell 4.0 Internasjonal